Design
| Designed for use on ships |
Sheath
| Construction | Mineral insulated |
| Material | SS 316 - ( Wst 1.4401 ) |
| Diameter "D" | 3 mm |
| Length "L" | Customer to specify |
| Process connection | 2 compression glands 1/4" NPT |
Cable
| Silicon insulated flexible cable, 240°C | |
| Cable length "K" | Customer to specify |
Sensor
| Single Pt 100 | |
| Accuracy | According IEC 751 class B |
| Style / Connection | 3 wire system ( Optional 4 wire system ) |
| Range | -100 / +250°C |
| Testing | Tested 200 Volt @ 20°C |
| Insulation | Minimum 100 M ohm |
Ordering code
| Model | DWR 6060 | ||
| Length "L" in mm | |||
| Length "K" in mm |