Design
Designed for use on ships | |
Approval | LLoyds register of shipping |
Certificate number | 1114 / TEK 100 4L |
Tube
Material | SS 316 - ( Wst 1.4401 ) |
Construction | Perforated tube |
Box
Material | Brass |
Cable entry | M24x1.5 cable gland |
Sensor
Single Pt100 | |
Style / Connection | 4 wire system |
Accuracy | 1/6 DIN 43760 |
Range | -40 / +70°C |
Testing | Tested 200 Volt @ 20°C |
Insulation | Minimum 100 M ohm |
Protection | IP 65 |